ATTENTION : ALL DISTRIBUTORS
RE: ALGAE-X TEST CONDUCTED AT BARLOWS CATERPILLAR ISANDO
On 4th November 2002 we provided a test unit to Barlows on behalf of their customer Suiferfontein Mine to confirm Algae-X's effectiveness. An LG-X 1500 Unit was tested on a CAT 3508 motor and the following results achieved:
| Engine State | ECM l/hr | KW | Exhaust Gas Temp. °C |
| High Idle | 80 | 28 | 247 |
| 1/4 Load | 90 | 156 | 334 |
| 1/2 Load | 127 | 305 | 404 |
| 3/4 Load | 162 | 455 | 468 |
| Full Load | 176 | 593 | 506 |
| Engine State | ECM l/hr | KW | Exhaust Gas Temp. °C |
| High Idle | 80 | 31 | 245 |
| 1/4 Load | 90 | 159 | 315 |
| 1/2 Load | 120 | 305 | 373 |
| 3/4 Load | 144 |
461 | 441 |
| Full Load | 174 | 593 | 483 |
| Improvement | 4.8L |
2.4 | 20.4° C |
| % Averaged |
4.25% | 5.21% | |
| 1/2 - full load |
5.8% | 5.88% | |
Discussions and feedback from our other CAT clients such as Optimum Colliery indicate a fuel saving of 6.73% and this tends to be a more realistic figure as the equipment operates mainly in the half to three-quarter load zones.
An interesting new point to us was the substantial reduction in exhaust gas temperatures which quite frankly I was unaware of! On querying this aspect with Algae-X International, I was advised that this was indeed a benefit of Algae-X and the result was obtained by providing a more optimum burn of the fuel in the combustion chamber and not continuing to burn on the exhaust transfer.
Sadly Barlows were not prepared to confirm these results on a CAT letterhead (I cannot understand why as the tests were repeated by them three times with exactly the same results, and a meeting with them yielded no negatives or concerns). Apparently, company policy restricts them from doing this.
Installation of Algae-X will not negate the warranty on CAT equipment, except of course if it is found that Algae-X caused the failure -- as you well know, an impossible scenario.
The gentlemen at Barlows who conducted the tests are:
Mr Pietie Aukamp, telephone number 011-9290000 or 082-9029377 and
Mr Hendrik Loods, telephone number 011-9290000 or 083-3274045.
They have, however, advised that they will be more than happy to confirm the above results telephonically, should a client require confirmation of such.
Hoping this information will assist.
Regards
RON MATTIG
DIRECTOR
NORTHEASTERN USA
Christian Smith
csmith [at] algae-x.net
SOUTHEASTERN USA
Bill Miller
billmiller [at] algae-x.net
MIDWESTERN USA
Max Givan
mgivan [at] algae-x.net
ROCKY MOUNTAIN & WESTERN USA
Bob McCann
bobmccann [at] algae-x.net
CANADA & CARIBBEAN
Bill O'Connell
billoconnell [at] algae-x.net
LATIN AMERICA
Enrique Osorio
eosorio [at] algae-x.net
INTERNATIONAL
Wout Lisseveld
International Inquiries